Service Manual Transistor Technical Articles CD Download Register Member Login Exit Sign
Home A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
. TV  .  Camera  .  Video camera  .  Notebook  .  Audio  .  Monitor  .  Projector  .  Air conditioning  .  Refrigerator  .  Printer  .  Duplicator  .  Fax machine  .  Mobile  .  Telephone  .  Washing machine  .  Cooker  .  Microwave  .  Other  .  
Your current location£ºHome > Technical Articles > Microwave

KD21B-TM-type microwave United States, without heating after a power failure boot repair method

Time£º2014-05-08 08:52:29  Source£ºNetwork  Author£ºUnknown  Clicks£º1127
  

Open the case , disconnect the high voltage circuit connections , with 500 multimeter R × 10k block detection voltage diodes , high voltage boost capacitor , were normal. Measured delay fuse 0.8A high pressure has been open , the resistance measured between the magnetron filament and the shell is 100Ω ( normal resistance should be infinite ) , indicating that the leakage has been damaged . Magnetron power test machine repair followed by a new fuse, the machine back to normal.CSXservice manual download site

Magnetron filament touch pole repair : damaged magnetron failure, is one of the common faults Repairs microwave oven. Prolonged use in wet environments , is likely to cause the output of the magnetron filament fixed insulation leakage fault occurs . How to make damaged magnetron change "waste " into treasure , by simple repairs on the plane will be able to re- use it? I used the service as follows:CSXservice manual download site
 CSXservice manual download site
1¡¢Remove the magnetron , the shell can be seen after Lid open the output of the magnetron filament insulation and high frequency induction coil .CSXservice manual download site

2¡¢the output of the magnetron filament outer insulation layer fixed small iron piece with the magnetron shell separated by Megger detection shell magnetron filament resistance , if it is infinite indicate can fix ; When is 0Ω , indicating magnetron internal breakdown , hitting pole, should be scrapped.CSXservice manual download site

3¡¢has been tested and determined to return to normal after the magnetron with AB glue magnetron filament insulation from both ends of the shell can be kept after 4mm glue , AB glue on until after the test machine installed everything correctly.CSXservice manual download site