Sony CCD-TRV46E battery charger can not open the machine fault repair method

Time£º2014-05-16 09:01:37  Source£ºNetwork  Author£ºUnknown  Clicks£º1165
  

Symptom: the machine can not be opened with a battery chargerDbaservice manual download site
After repair: Check DD-117 BOARD, fuses are intact, measuring IC604 MODE CONTROL IC 3V voltage problems, measured on VC-215 BOARD CN915 (36) pin voltage is normal, after IC602 RESET to IC604 (86) (87) feet 3V No, the failure to narrow to around IC602. IC602 each measuring capacitance around and found C615 leakage, replacement boot OK.Dbaservice manual download site